{"id":2762,"date":"2026-11-14T15:54:19","date_gmt":"2026-11-14T15:54:19","guid":{"rendered":"https:\/\/aa1.es\/?p=2762"},"modified":"2026-11-14T20:27:13","modified_gmt":"2026-11-14T20:27:13","slug":"advanced-chemical-analysis-by-lc-ms-ms","status":"publish","type":"post","link":"https:\/\/aa1.es\/?p=2762","title":{"rendered":"Advanced Chemical Analysis by LC-MS\/MS"},"content":{"rendered":"\n<div class=\"wp-block-uagb-info-box uagb-block-25555b74 uagb-infobox__content-wrap  uagb-infobox-icon-left-title uagb-infobox-left uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-left-title-image\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M0 256C0 114.6 114.6 0 256 0C397.4 0 512 114.6 512 256C512 397.4 397.4 512 256 512C114.6 512 0 397.4 0 256zM371.8 211.8C382.7 200.9 382.7 183.1 371.8 172.2C360.9 161.3 343.1 161.3 332.2 172.2L224 280.4L179.8 236.2C168.9 225.3 151.1 225.3 140.2 236.2C129.3 247.1 129.3 264.9 140.2 275.8L204.2 339.8C215.1 350.7 232.9 350.7 243.8 339.8L371.8 211.8z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\">LC-MS\/MS<\/h3><\/div><\/div><p class=\"uagb-ifb-desc\">Hyperspectral Imaging Analysis in the Vis-NIR and NIR Ranges<\/p><\/div><\/div>\n\n\n\n<div style=\"height:45px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">Overview<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Liquid chromatography coupled with tandem mass spectrometry (LC-MS\/MS) is an analytical technique that combines the separation of compounds by liquid chromatography (LC) with their detection and identification by mass spectrometry (MS\/MS). This combination allows the analysis of different compounds in complex samples. It is particularly useful for the identification and quantification of bioactive compounds, as well as for the development of analytical methods for different types of samples.<\/p>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-250407f1\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">How does LC-MS\/MS work?<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\"><br>LC-MS\/MS analysis is based on three main stages: chromatographic separation, ionisation and mass spectrometric analysis.<\/p>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-11e43136\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-bf7f945a uagb-infobox__content-wrap  uagb-infobox-icon-left-title uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-left-title-image\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 448 512\"><path d=\"M437.2 403.5L319.1 215L319.1 64h7.1c13.25 0 23.1-10.75 23.1-24l-.0002-16c0-13.25-10.75-24-23.1-24H120C106.8 0 96.01 10.75 96.01 24l-.0002 16c0 13.25 10.75 24 23.1 24h7.1L128 215l-117.2 188.5C-18.48 450.6 15.27 512 70.89 512h306.2C432.7 512 466.5 450.5 437.2 403.5zM137.1 320l48.15-77.63C189.8 237.3 191.9 230.8 191.9 224l.0651-160h63.99l-.06 160c0 6.875 2.25 13.25 5.875 18.38L309.9 320H137.1z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h6 class=\"uagb-ifb-title\"><strong>1. Liquid chromatography (LC)<\/strong><\/h6><\/div><\/div><p class=\"uagb-ifb-desc\">The sample is introduced into the chromatographic system. Inside the column the different compounds are separated depending on the interactions between them, the mobile phase and the stationary phase. As a result, each compound leaves the column at a different retention time before entering the mass spectrometer.<\/p><\/div><\/div><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"341\" src=\"https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Funcionamiento-LC-1024x341.png\" alt=\"\" class=\"wp-image-2767\" srcset=\"https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Funcionamiento-LC-1024x341.png 1024w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Funcionamiento-LC-300x100.png 300w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Funcionamiento-LC-768x256.png 768w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Funcionamiento-LC-1536x512.png 1536w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Funcionamiento-LC-2048x683.png 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-eda868e7 uagb-infobox__content-wrap  uagb-infobox-icon-left-title uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-left-title-image\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 384 512\"><path d=\"M381.2 172.8C377.1 164.9 368.9 160 360 160h-156.6l50.84-127.1c2.969-7.375 2.062-15.78-2.406-22.38S239.1 0 232 0h-176C43.97 0 33.81 8.906 32.22 20.84l-32 240C-.7179 267.7 1.376 274.6 5.938 279.8C10.5 285 17.09 288 24 288h146.3l-41.78 194.1c-2.406 11.22 3.469 22.56 14 27.09C145.6 511.4 148.8 512 152 512c7.719 0 15.22-3.75 19.81-10.44l208-304C384.8 190.2 385.4 180.7 381.2 172.8z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h6 class=\"uagb-ifb-title\">2. <strong>Ionisation (ESI)<\/strong><\/h6><\/div><\/div><p class=\"uagb-ifb-desc\">After chromatographic separation, these compounds enter the ion source to be converted into gas-phase ions and depending on the chemical characteristics of the compounds, the analysis can be performed in positive or negative ionisation mode.<\/p><\/div><\/div><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\"><img decoding=\"async\" width=\"1024\" height=\"409\" src=\"https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/ESI-1024x409.png\" alt=\"\" class=\"wp-image-2788\" srcset=\"https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/ESI-1024x409.png 1024w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/ESI-300x120.png 300w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/ESI-768x307.png 768w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/ESI-1536x614.png 1536w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/ESI.png 1983w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-0172038a uagb-infobox__content-wrap  uagb-infobox-icon-left-title uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-left-title-image\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 576 512\"><path d=\"M0 80C0 53.49 21.49 32 48 32H144C170.5 32 192 53.49 192 80V96H384V80C384 53.49 405.5 32 432 32H528C554.5 32 576 53.49 576 80V176C576 202.5 554.5 224 528 224H432C405.5 224 384 202.5 384 176V160H192V176C192 177.7 191.9 179.4 191.7 180.1L272 288H368C394.5 288 416 309.5 416 336V432C416 458.5 394.5 480 368 480H272C245.5 480 224 458.5 224 432V336C224 334.3 224.1 332.6 224.3 331L144 224H48C21.49 224 0 202.5 0 176V80z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h6 class=\"uagb-ifb-title\">3. <strong>Tandem mass spectrometry (MS\/MS)<\/strong><\/h6><\/div><\/div><p class=\"uagb-ifb-desc\">The generated ions enter the triple-quadrupole mass analyser, which consists of three main components: Q1, Q2 and Q3. The first quadrupole (Q1) selects the precursor ion according to its mass-to-charge ratio (m\/z). After this, the ion enters the collision cell (Q2), where it interacts with argon gas and undergoes fragmentation. Finally, the third quadrupole (Q3) selects the resulting product ions before they reach the detector. This process provides information that can be used for the identification and quantification of specific compounds.<\/p><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-5bee7331\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\"><img decoding=\"async\" width=\"1024\" height=\"341\" src=\"https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Espectrometria-de-masas-en-tandem-1024x341.png\" alt=\"\" class=\"wp-image-2792\" srcset=\"https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Espectrometria-de-masas-en-tandem-1024x341.png 1024w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Espectrometria-de-masas-en-tandem-300x100.png 300w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Espectrometria-de-masas-en-tandem-768x256.png 768w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Espectrometria-de-masas-en-tandem-1536x512.png 1536w, https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/Espectrometria-de-masas-en-tandem-2048x683.png 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-beb47b8a\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">What is LC-MS\/MS used for?<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">LC-MS\/MS is used in a wide range of fields, including food science, pharmaceutical research, environmental analysis, biotechnology and the chemical industry. This is mainly due to its ability to separate, identify and quantify compounds, making it suitable for different purposes, from routine quality control to research and product development.<br>In the pharmaceutical industry, for example, it is used throughout drug development, as well as for the analysis of pharmaceutical products and the study of their stability. In food science, it can be applied to assess product quality and safety, characterise food products and develop analytical methods. It is also a useful tool in environmental studies, where it helps monitor chemical substances and investigate possible sources of contamination. In addition, its use in biotechnology and other industrial sectors has increased, particularly when the analysis of complex samples or the development of specific analytical procedures is required.<br>In research, LC-MS\/MS is often used to identify and quantify compounds in complex samples. It can also be applied to compare different extraction procedures and assess how experimental conditions affect the compounds being analysed. Another advantage is that several target compounds can be monitored in a single analysis, which makes it possible to obtain more information from each sample and compare the results obtained under different conditions.<\/p>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-31bd5b24\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">LC-MS\/MS and the study of bioactive compounds<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">LC-MS\/MS is also particularly useful in the study of bioactive compounds in food products, plant materials and agro-industrial by-products. Since these samples may contain a wide variety of compounds, their analysis requires techniques capable of separating the different components and determining their presence and concentration. In this context, LC-MS\/MS can be used to characterise extracts, compare extraction conditions and evaluate the recovery of compounds of interest. The information obtained can help to better understand the chemical composition of these materials and identify suitable conditions for their further use.<\/p>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-397bda24\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">Key advantages<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">The main advantages of LC-MS\/MS include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>High sensitivity, allowing the detection of compounds at low concentrations<\/li>\n\n\n\n<li>High selectivity through the combination of chromatographic separation and mass spectrometric detection<\/li>\n\n\n\n<li>Quantification of specific compounds using appropriate calibration methods<\/li>\n\n\n\n<li>Analysis of complex samples following suitable sample preparation<\/li>\n\n\n\n<li>Possibility of analysing different families of compounds by developing specific analytical methods<\/li>\n\n\n\n<li>Simultaneous monitoring of several target compounds within the same analytical run<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Overall, LC-MS\/MS represents a useful analytical tool for the characterisation of complex food matrices and the study of compounds with potential added value.<\/p>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-cd73f5d8\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><\/div><\/div>\n\n\n\n<h5 class=\"wp-block-heading\">AA1 Equipment:<\/h5>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-3ada7b8a uagb-infobox__content-wrap  uagb-infobox-icon-left-title uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin fondo-gris-claro has-custom-css wp-custom-css-68ee8372\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-left-title-image\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 384 512\"><path d=\"M361 215C375.3 223.8 384 239.3 384 256C384 272.7 375.3 288.2 361 296.1L73.03 472.1C58.21 482 39.66 482.4 24.52 473.9C9.377 465.4 0 449.4 0 432V80C0 62.64 9.377 46.63 24.52 38.13C39.66 29.64 58.21 29.99 73.03 39.04L361 215z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h6 class=\"uagb-ifb-title\"><strong>UPLC-MS\/MS Xevo TQ-S Acquity (Waters)<\/strong><\/h6><\/div><\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-3ef41f11 uagb-infobox__content-wrap  uagb-infobox-icon-left-title uagb-infobox-left uagb-infobox-image-valign-top wp-block-uagb-info-box--has-margin fondo-gris-claro has-custom-css wp-custom-css-4bf6864a\"><div class=\"uagb-infobox-margin-wrapper\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-left-title-image\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 384 512\"><path d=\"M361 215C375.3 223.8 384 239.3 384 256C384 272.7 375.3 288.2 361 296.1L73.03 472.1C58.21 482 39.66 482.4 24.52 473.9C9.377 465.4 0 449.4 0 432V80C0 62.64 9.377 46.63 24.52 38.13C39.66 29.64 58.21 29.99 73.03 39.04L361 215z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h6 class=\"uagb-ifb-title\"><strong>UPCL-TSQ Quantis (ThermoScientific)<\/strong><\/h6><\/div><\/div><\/div><\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Liquid chromatography coupled with tandem mass spectrometry (LC-MS\/MS) is an analytical technique that combines the separation of compounds by liquid chromatography (LC) with their detection and identification by mass spectrometry (MS\/MS). This combination allows the analysis of different compounds in complex samples. It is particularly useful for the identification and quantification of bioactive compounds, as well as for the development of analytical methods for different types of samples.<\/p>\n","protected":false},"author":1,"featured_media":2842,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","footnotes":"","_members_access_role":[],"_members_access_error":""},"categories":[11],"tags":[],"class_list":["post-2762","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-servicio"],"uagb_featured_image_src":{"full":["https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/LC-MS-wp.jpg",1745,1099,false],"thumbnail":["https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/LC-MS-wp-150x150.jpg",150,150,true],"medium":["https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/LC-MS-wp-300x189.jpg",300,189,true],"medium_large":["https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/LC-MS-wp-768x484.jpg",768,484,true],"large":["https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/LC-MS-wp-1024x645.jpg",800,504,true],"1536x1536":["https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/LC-MS-wp-1536x967.jpg",1536,967,true],"2048x2048":["https:\/\/aa1.es\/wp-content\/uploads\/2026\/11\/LC-MS-wp.jpg",1745,1099,false]},"uagb_author_info":{"display_name":"AA1 Grupo de Investigaciones Agrarias y Alimentarias","author_link":"https:\/\/aa1.es\/?author=1"},"uagb_comment_info":0,"uagb_excerpt":"Liquid chromatography coupled with tandem mass spectrometry (LC-MS\/MS) is an analytical technique that combines the separation of compounds by liquid chromatography (LC) with their detection and identification by mass spectrometry (MS\/MS). This combination allows the analysis of different compounds in complex samples. It is particularly useful for the identification and quantification of bioactive compounds, as&hellip;","_links":{"self":[{"href":"https:\/\/aa1.es\/index.php?rest_route=\/wp\/v2\/posts\/2762","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aa1.es\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/aa1.es\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/aa1.es\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aa1.es\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2762"}],"version-history":[{"count":36,"href":"https:\/\/aa1.es\/index.php?rest_route=\/wp\/v2\/posts\/2762\/revisions"}],"predecessor-version":[{"id":2846,"href":"https:\/\/aa1.es\/index.php?rest_route=\/wp\/v2\/posts\/2762\/revisions\/2846"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aa1.es\/index.php?rest_route=\/wp\/v2\/media\/2842"}],"wp:attachment":[{"href":"https:\/\/aa1.es\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2762"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/aa1.es\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2762"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/aa1.es\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2762"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}